76. In the determination of iron in wastewater, the met

The sale of this product is suspended.

Try to search similar items from other sellers.

Sold: 1 last one 17.10.2020
Refunds: 0

Uploaded: 05.08.2019
Content: 76.rar 14,32 kB

Product description


76. In the determination of iron in wastewater, the method of standard additives was used. For this purpose, 20.00 ml of waste water was poured into two volumetric flasks with a capacity of 25.00 ml, and 2.00 ml of a standard solution of iron with a concentration of 0.50 μg / ml was poured into one of them. The volumes of solutions in both volumetric flasks brought to the mark with distilled water. The atomic absorption of these solutions at 248.32 nm is 25 and 15 units, respectively.
Determine the concentration (mg / l) of iron in the waste water.

Additional information

If you do not open the file - install the RAR archiver. Inside the archive you will find a solution in Word format.

Feedback

0
Period
1 month 3 months 12 months
0 0 0
0 0 0
In order to counter copyright infringement and property rights, we ask you to immediately inform us at support@plati.market the fact of such violations and to provide us with reliable information confirming your copyrights or rights of ownership. Email must contain your contact information (name, phone number, etc.)