60. Option 2 When determining platinum elements (Pd, Pt

Affiliates: 0,01 $how to earn
Pay with:
i agree with "Terms for Customers"
Sold: 0 Uploaded: 05.08.2019
Content: 60.rar 59,1 kB

Product description

60. Option 2
When determining platinum elements (Pd, Pt, Rh, Ir), the sample weight of 1.0000 g was transferred to a solution with a volume of 10.00 ml after decomposition and corresponding treatment. Samples of 100.00 μl of the obtained solution were placed in an electrothermal atomizer (graphite tube) of an automatic atomic absorption spectrophotometer and an absorption signal of the analytical line of the element in the form of a peak height hx, mm was recorded on the chart tape of the recorder.
To construct the calibration graph, 100.00 μl of standard solutions of salts of platinum metals were sequentially injected into the atomizer and the values ​​of h mm peaks were measured.
Sst (Pd), µg / ml 0.01 0.05 0.10
h (Pd) mm 8.5 45.0 90.0

Sst (Pt), µg / ml 0.04 0.08 0.12
h (Pt) mm 17.0 34.5 52.0

Sst (Rh), µg / ml 0.01 0.05 0.10
h (Rh), mm 12.0 59.0 118.0

Cst (Ir), µg / ml 0.10 0.20 0.40
h (Ir), mm 12.0 24.0 48.0

Calculate the concentration (g / t) of palladium, platinum, rhodium and iridium in the samples for the following options:
h, mm for line
Pd - 44.0
Pt - 39.0
Rh - 74.0
Ir - 35.0

Additional information

If you do not open the file - install the RAR archiver. Inside the archive you will find a solution in Word format.

Feedback

0
No feedback yet.
In order to counter copyright infringement and property rights, we ask you to immediately inform us at support@plati.market the fact of such violations and to provide us with reliable information confirming your copyrights or rights of ownership. Email must contain your contact information (name, phone number, etc.)