51. Option 1
A standard cerium solution was prepared by dissolving 0.0500 g in a 250.0 ml mixture of perchloric and hydrochloric acids. In flasks with a capacity of 25.00 ml were placed: 2.50; 3.00; 3.50; 4.00; 4.50; 5.00 ml of standard solution, ammonia, hydrogen peroxide, nitrilotriacetic acid was added and diluted to the mark with water. When photometry relative to the first solution received:
Vst, ml 3.00; 3.50; 4.00; 4.50; 5.00
Aot 0.135 0.270 0.405 0.545 0.680
A portion of lanthanide oxides with a mass of 0.0500 g was dissolved, the necessary reagents were added, diluted to 25.00 ml, and photometric, as in the construction of the calibration curve.
Calculate the mass fraction in the sample of lanthanide oxides using the following data.
Aoth. X = 0,345

Additional information

If you do not open the file - install the RAR archiver. Inside the archive you will find a solution in Word format.

Feedback

0
No feedback yet.
In order to counter copyright infringement and property rights, we ask you to immediately inform us at support@plati.market the fact of such violations and to provide us with reliable information confirming your copyrights or rights of ownership. Email must contain your contact information (name, phone number, etc.)